Pipes
Showing all 5 results
-
Flow Measurement and Flow Study
Liquid Sedimentation Apparatus
The apparatus is designed to study the settling characteristics and particle sizes of suspended solid.
Five transparent glass sediment tubes are mounted vertically on a rigid frame. The rear panel is translucent with back lighting. Scales are provided on the tubes. The tubes can be removed for washing, filling or mixing of solid particles. Sedimentation rate is observed using a stopwatch.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Settling rate curve.
- Effect of particle size distribution.
- Effect of suspension height on sedimentation rates.
- Effect of concentration on sedimentation rate.
- Effect of flocculent.
TECHNICAL DATAGlass tubes 5 Stop watch 1 Beakers 3 Lamps 4 Specific gravity bottle 1 Software for data display and analysis by computer (separately supplied). Power supply 220 V, 1 Ph, 50 Hz. Other power supply is available on request. (0 reviews) -
Flow Measurement and Flow Study
Pipe Network Apparatus
This equipment is designed to measure the flows and pressure drops in a wide range of pipe network configuration e.g. individual pipes, series pipes, parallel pipes, doubling pipes, and ring main.
Pressure drops is measured by manometers. Fittings connection is by screwed coupling with “O” rings. Pressure tapping is by small ball valves with quick connection. The apparatus and accessories are attached on a panel to the Hydraulics Bench (separately supplied).
Instruction manual is also included.
TYPICAL EXPERIMENTS- Head loss and flow with various system components.
- Characteristics of various pipe networks e.g., series pipes, parallel pipes, and other combinations.
TECHNICAL DATATest pipes 5 pipes in 4 different diameters. Fittings for various pipe configuration Differential pressure measurement: – Water manometer with hand air pump – Differential pressure gauge Hydraulics Bench HB100N or HB100 Software for data display and analysis by computer (separately supplied). Power supply 220 V, 1 Ph, 50 Hz. Other power supply is available on request. (0 reviews) -
Flow Measurement and Flow Study
Piping Loss Apparatus (Small)
This is a comprehensive unit for studying the friction losses in pipes, pipe fittings and valves at various flow rates.
All friction loss components are arranged on a water proof panel which is attached to a floor standing steel frame. The apparatus is to be used with a Hydraulics Bench (separately supplied) or an outside water supply.
The loss is measured by differential pressure using manometers and differential pressure gauge. Pressure tapping is by small ball valves with quick connection. All pressure taps are connected by flexible hoses to a set of specially arranged manifolds such that differential pressure across any component can be measured simply by opening valves without removing the hoses.
The unit is on a steel frame with adjustable footings.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Friction losses in straight pipes at various flow rates.
- Friction losses in pipe fittings, valves, sudden expansion and contraction at various flow rates.
TECHNICAL DATAFriction loss components: – Linear pipes, PVC 3 different diameters. – Short radius bends 2 ea. – Regular elbow 1 ea. – 45o elbows 2 ea. – Valves Gate, globe, ball, and check – Other components Tee section Sudden expansion Sudden contraction Measuring instruments – Water meter and stop watch. – Water manometer with hand air pump – Differential pressure gauge Software for data display and analysis by computer (separately supplied). (0 reviews) -
Flow Measurement and Flow Study
Piping Loss Test Set – Large
This is a self-contained water circulating unit for studying the friction losses in pipes, pipe fittings, and valves; and to determine coefficients of discharge for primary flow measuring devices at various flow rates.
The unit consists of a pump, a storage tank and a water proof panel on which all friction loss components and the flow measuring devices are arranged.
Friction loss is measured by a pressure drop and coefficient of discharge is determined from a pressure drop and a flow rate. Flow rate is obtained from a water meter and a stop watch. The pressure drop is measured by differential pressure using manometer and differential pressure gauge. Pressure tapping is by small ball valves with quick connection. All pressure taps are connected by flexible hoses to a set of specially arranged manifolds such that differential pressure across any component can be measured simply by opening valves without removing the hoses. The unit is on a steel frame on wheels.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Friction losses in straight pipes at various flow rates.
- Friction losses in pipe fittings, valves, sudden expansion and contraction at various flow rates.
- Friction losses in primary flow measuring devices and comparison of coefficients of discharge at various flow rates.
TECHNICAL DATAPrimary flow measuring devices made from clear acrylic: – Venturi tube – Orifice plate – Pitot tube Friction loss components: – Linear pipes, PVC 3 different diameters. – Linear pipe, stainless steel 1 ea. – Valves Gate, globe, ball and check – Short radius bends 2 ea. – Long radius bends 2 ea. – Regular elbow 1 ea. – 45o elbows 2 ea. – 45o Y 1 ea. – Other components Tee section Inline strainer Sudden expansion Sudden contraction Measuring instruments – Water meter and stop watch. – Water manometer with hand air pump – Differential pressure gauge Software for data display and analysis by computer (separately supplied). Power supply 220 V, 1 Ph, 50 Hz. Other power supply is available on request. (0 reviews) -
Flow Measurement and Flow Study
Piping Loss Test Set – Small
This is a self-contained unit for studying the friction loss in pipes, pipe fittings and valves at various flow rates.
The unit consists of a pump, a storage tank and a water proof panel on which all friction loss components are arranged.
The loss is measured by differential pressure using manometer and differential pressure gauge. Pressure tapping is by small ball valves with quick connection. All pressure taps are connected by flexible hoses to a set of specially arranged manifolds such that differential pressure across any component can be measured simply by opening valves without removing the hoses. The unit is on a steel frame on wheels.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Friction losses in straight pipes at various flow rates.
- Friction losses in pipe fittings, valves, sudden expansion and contraction at various flow rates.
TECHNICAL DATAFriction loss components – Linear pipes, PVC 3 different diameters. – Short radius bends 2 ea. – Regular elbow 1 ea. – 45o elbows 2 ea. – Valves Gate, globe, ball, and check – Other components Tee section, Sudden expansion Sudden contraction Measuring Instruments – Water meter and stop watch – Water manometer with hand air pump – Differential pressure gauge Software for data display and analysis by computer (separately supplied). Power supply 220 V, 1 Ph, 50 Hz. Other power supply is available on request. (0 reviews)