Air Conditioning System
Showing all 4 results
-
Air Flow and Thermodynamics
Air-To-Water Heat Pump
A table top air conditioning system is used to demonstrate how heat is transferred from air to water.
A water cooled heat exchanger is used as a condenser while the liquid refrigerant is evaporated in an air cooled evaporator. Instruments are provided for measurement of temperatures, pressures, and water flow rate. The system requires outside water supply.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Design and operation of air to water heat pump.
- P-h diagram. . Energy balances.
- Coefficient of performance.
- Overall heat transfer coefficients for evaporator and condenser.
- Effects of loads variation.
TECHNICAL DATACompressor 0.37 W Refrigerant R134a Evaporator Air cooled. Condenser Co-axial coil heat exchanger Measuring instruments: − Pressure gauges 2 ea. − Water rotameter 1 ea. − Sensors with digital display Temperature for compressor inlet and outlet, condenser outlet, evaporator inlet and condenser cooling water inlet and outlet Software for data display and analysis by computer (separately supplied). Power supply 220V 1Ph 50Hz. Other power supply is available on request. (0 reviews) -
Air Flow and Thermodynamics
Car Air Conditioning System
The trainer unit contains a belt-driven compressor, an air-cooled condenser and an evaporator with cold air outlet. All components used in the trainer are normal automotive parts. A motor is used to drive to the compressor by a V-belt and step pulleys.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Study of layout and process diagram.
- Recognition of typical faults and repair on an air conditioner.
- Simulation of system faults.
- Thermodynamic cyclic process.
- Observation of pressures and temperatures.
TECHNICAL DATACompressor, automotive type 1 ea., with magnetic clutch Condenser Air cooled with fan Refrigerant R-134a Drive motor 3.7 kW Speed adjustment Step pulleys Filter / dryer 1 ea. Evaporator Automotive type Measuring instruments – Pressure gauges 2 ea. – Sensors with digital display Temperature for compressor inlet and outlet, condenser outlet, expansion valve
outlet, and air–side at evaporator outlet.Software for data display and analysis by computer (separately supplied). Main power supply 220 V, 1 Ph, 50Hz. Other power supplies available on request. (0 reviews) -
Air Flow and Thermodynamics
Laboratory Air Conditioning System
This is an open circuit air conditioning system with transparent window.
The unit consists of a fan, a compressor and condenser, a humidifier, a preheater, a cooling unit, a reheater, and measuring instruments.
Variable speed inlet fan deliver air to the duct. A steam humidifier injects moisture to the duct inlet. The humidified air passes through a preheater, a cooling unit, and a reheater before exit to the atmosphere. Steam generator, compressor and condenser are underneath the duct.
Instruments are provided for measurement of temperatures, pressures, humidity, power, air flow rate, and refrigerant flow rate.
The unit is on a steel frame on wheels.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Familiarization with an open air conditioning system and components.
- Determination of humidification, preheating, cooling and dehumidification, and reheating processes.
- Energy balance in the preheater, evaporator, and reheater.
- Demonstration of humidification, preheating, cooling and dehumidification, and reheating processes on psychrometric chart.
- Demonstration of refrigeration cycle on Pressure-Enthalpy diagram of the refrigerant R134a.
TECHNICAL DATAAir duct 250 x 250 mm, stainless steel sheet Fan with speed controller – Maximum airflow rate 750 m3/h Humidifier 1500 W Preheater 3 x 500 W Reheater 3 x 500 W Evaporator 250 x 250 mm Compressor 0.55 kW Refrigerant R134a Temperature controller 1 ea. – Sensors with digital display - Air flow rate, velocity sensor, 0-3 m/s
- Temperature at duct inlet, humidifier, preheater inlet and outlet, evaporator outlet, reheater outlet, compressor inlet and outlet and condenser outlet.
- Power for compressor, humidifier, preheater and reheater
Refrigerant rotameter 1 ea. Portable temperature / humidity meter 1 ea. Pressure gauges 2 ea. Software for data display and analysis by computer (separately supplied). Power supply 380 V, 3 Ph, 50Hz. Other power supply is available on request. (0 reviews) -
Air Flow and Thermodynamics
Recirculating Air Conditioning Unit (with Climatic Chamber)
This is a recirculating air conditioning unit with transparent windows and a climatic chamber.
Inlet air is cooled and preheated by a heater and latent heat by a humidifier before entering the climatic chamber for demonstration of climate control. The air in the climatic chamber is further heated by a heater and a humidifier before leaving. A fan after the preheater circulates the air. Part of the air leaving the climatic chamber is vented and the remaining is recirculated with make up fresh air entering the inlet duct. The amount of air recirculation is controlled by ventilation flaps. Steam generator, compressor and condenser are underneath the duct.
Measuring instruments are provided for air flow rate, and temperature and humidity at various stages. Additional instruments are provided for measurement of refrigerant flow rate, temperature and pressure as well as power for the compressor and heat sources.
The unit is on steel frame on wheels.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Familiarization with recirculating air conditioning system and components.
- Determination of preheating, cooling and dehumidification, humidification, and reheating processes.
- Energy balance in the preheater, evaporator, and reheater.
- Demonstration of preheating, cooling and dehumidification, humidification, reheating, and mixing processes on psychrometric chart.
- Demonstration of refrigeration cycle on Pressure-Enthalpy diagram of the refrigerant R134a.
- Determination of recirculating and mixing process of moist air.
- Effects of climatic chamber heat loads.
TECHNICAL DATAAir duct 250 x 250 mm section. Climatic chamber Approx. 180 L Fan Adjustable speed – Maximum airflow rate Approx. 750 m3/h Humidifier 3000 W, adjustable. Preheater 3x 400W, adjustable Reheater 3x 200W, adjustable Evaporator 250 x 250 mm. Compressor Approx. 0.55 kW. Refrigerant R134a Temperature controller 1 ea. Measuring instruments – Sensors with digital display - Air flow rate , velocity sensor
- Temperatures at duct inlet, humidifier preheater inlet and outlet, evaporator outlet, reheater outlet, compressure inlet and outlet and condenser outlet.
- Power measurement for compressor, humiditier, preheater and reheater
– Portable temperature/humidity meter 0-50°C 10-90% RH, at duct inlet preheater inlet and climatic chamber outlet – Refrigerant rotameter Approx. 0.15-1.5 Lpm – Pressure gauges 2 ea. Software for data display and analysis by computer (separately supplied). Power supply 380 V 3 Ph 50 Hz. Other power supply is available on request. (0 reviews)