Mechanics of Fluids
Showing 10–18 of 112 results
-
Pump Test Set
Compact Centrifugal Pump Test Set – Motor Dynamometer
This is a self-contained bench top unit for studying the centrifugal pump characteristics.
The unit consists of a storage tank and a centrifugal pump with a motor dynamometer on a steel base for measurement of TRUE pump input power and measuring instruments.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Flow rate vs head at various speeds.
- Pump input, output and true efficiency at various speeds.
TECHNICAL DATAPump ratings – Maximum flow rate 80 Lpm – Maximum head 18 m water Measuring instruments – Flow rate Water meter and stop watch – Pressure Pressure gauges at pump suction and discharge – Sensors with digital display for speed and torque Software for data display and analysis by computer (separately supplied). Power supply 220V, 1 Ph, 50 Hz. Other power supply is available on request. (0 reviews) -
Pump Test Set
Compact Centrifugal Pump Test Set – Multi Speed
This is a self-contained bench top unit for studying the centrifugal pump flow rate vs head at three different speeds.
The unit consists of a storage tank and a centrifugal pump with multi speed motor on a steel base, and measuring instruments.
Instruction manual is also included.
TYPICAL EXPERIMENTSFlow rate vs head at three different speeds.
TECHNICAL DATAPump ratings – Speeds 3 different speeds. – Maximum flow rate 70 Lpm – Maximum head 7 m water Measuring instruments – Pressure Pressure gauges at pump suction and discharge – Flow rate Water meter and stop watch Software for data display and analysis by computer (separately supplied). Power supply 220 V, 1 Ph, 50Hz. Other power supply is available on request. (0 reviews) -
Pump Test Set
Compact Centrifugal Pump Test Set – Variable Speed
This is a self-contained bench top unit for studying the centrifugal pump flow rate vs head at various speeds.
The unit consists of a storage tank and a centrifugal pump with motor on a steel base, advanced inverter and measuring instruments.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Flow rate vs head.
- Pump input, output and overall efficiency at various speeds.
TECHNICAL DATAPump ratings – Maximum flow rate 80 Lpm – Maximum head 18 m water Measuring instruments – Pressure Pressure gauges at pump suction and discharge – Flow rate Water meter and stop watch – Speed and motor input power indicator Advanced inverter Software for data display and analysis by computer (separately supplied). Power supply 220 V, 1 Ph, 50 Hz. Other power supply is available on request. (0 reviews) -
Turbine Test Set
Compact Cross Flow Turbine Test Set
This is a self contained bench top set for studying the Cross Flow turbine characteristics under various flow rates
and heads.The unit consists of a storage tank, a pump, a turbine, a dynamometer, and measuring instruments.
The adjustable nozzle directs the water jet tangentially to the runner.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Torque vs speed at various heads and flow rates.
- Power output vs speed for various heads and flow rates.
- Efficiency vs speed for a given head and flow rate.
- Racing characteristics.
TECHNICAL DATATurbine: – Construction - Stainless steel runner and nozzle
- Stainless steel casing with transparent window
– Ratings - Over 400 W of brake power
- Maximum speed approx. 1500 rpm
Pump ratings: – Motor 2.2 kW Dynamometer Water cooled mechanical brake absorber with anti splashing system Measuring instruments – Torque Spring balance – Pressure Pressure gauge – Sensors with digital display Flow rate and speeds Software for data display and analysis by computer (separately supplied). Power supply 220 V, 1 Ph, 50 Hz. Other power supply is available on request. (0 reviews) -
Turbine Test Set
Compact Francis Turbine Test Set
This is a self contained bench top set for studying the Francis turbine characteristics under various flow rates and heads.
The unit consists of a storage tank, a pump, a turbine, a dynamometer, and measuring instruments.
The adjustable guide vanes direct water spirally to the runner.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Torque vs speed at various heads and flow rates.
- Power output vs speed for various heads and flow rates.
- Efficiency vs speed for a given head and flow rate.
- Racing characteristics.
TECHNICAL DATATurbine: – Construction - Bronze runner, with adjustable guide vanes
- Non corrosion metal casing with transparent window to observe guide vane position
– Ratings Over 400 W of brake power Pump ratings – Motor 2.2 kW Dynamometer Water cooled mechanical brake absorber with anti splashing system Measuring instruments – Torque Spring balance – Pressure Pressure gauge – Sensors with digital display Flow rate and speed Software for data display and analysis by computer (separately supplied). Power supply 220 V, 1 Ph, 50 Hz. Other power supply is available on request. (0 reviews) -
Pump Test Set
Compact Gear Pump Test Set – Fixed Speed
This is a self-contained bench top unit for studying the gear pump flow rate vs head at a fixed speed.
The unit consists of a storage tank and a gear pump with a motor on a steel base, and measuring instruments. It is to be used with oil or glycol.
Instruction manual is also included.
TYPICAL EXPERIMENTSFlow rate vs head.
TECHNICAL DATAPump ratings – Maximum flow rate 20 Lpm – Maximum head 30 m water – Pressure relief valve Built-in Measuring instruments: – Pressure Pressure gauges at pump suction and discharge – Flow rate Oil meter and stop watch Software for data display and analysis by computer (separately supplied). Power supplied 220 V, 1 Ph, 50Hz. Other power supply is available on request. (0 reviews) -
Pump Test Set
Compact Gear Pump Test Set – Variable Speed
This is a self-contained bench top unit for studying the gear pump flow rate vs head at various speeds.
The unit consists of a storage tank and a gear pump with motor on a steel base, advanced inverter and measuring instruments.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Flow rate vs head.
- Pump input, output and overall efficiency at various speed.
TECHNICAL DATAPump ratings – Maximum flow rate 20 Lpm – Maximum head 30 m water Speed control Advanced inverter Measuring instruments – Pressure Pressure gauges at pump suction and discharge – Flow rate Oil meter and stop watch – Speed and motor input power indicator Advanced inverter Software for data display and analysis by computer (separately supplied). Power supply 220 V, 1 Ph, 50Hz. Other power supply is available on request. (0 reviews) -
Turbine Test Set
Compact Kaplan Turbine Test Set
This is a self contained bench top set for studying the Kaplan turbine characteristics under various flow rates and heads.
The unit consists of a storage tank, a pump, a Kaplan turbine, a dynamometer, and measuring instruments. The adjustable guide vanes direct water helically to the runner.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Torque vs speed at various heads and flow rates.
- Power output vs speed for various heads and flow rates.
- Efficiency vs speed for a given head and flow rate.
- Racing characteristics.
TECHNICAL DATATurbine: – Construction - Fixed blade metal runner
- Non corrosion metal casing with adjustable guide vanes with transparent window to observe runner and guide vane position
– Ratings Over 400W of brake power Pump ratings : – Motor 2.2 kW Dynamometer Water cooled mechanical brake absorber with anti splashing system Measuring instruments – Torque Spring balance – Pressure Pressure gauge – Sensors with digital display Flow rate and speed Software for data display and analysis by computer (separately supplied). Power supply 220 V, 1 Ph, 50 Hz. Other power supply is available on request. (0 reviews) -
Pump Test Set
Compact Multi Pump Test Set – Inverter Speed Control
This is a compact self-contained bench top set for studying the characteristics for various types of pumps.
The unit consists of four different types of pump namely-centrifugal, turbine, reciprocating and axial flow pumps and a common storage tank, measuring instruments. Speed control is by an advanced inverter. By manipulating flow control valves and a selector switch, each pump can be operated individually.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Flow rate vs head at various speeds.
- Pump input, output, and overall efficiency at various speeds.
- Effect of pulse chamber for reciprocating pump.
TECHNICAL DATAPumps ratings: – Centrifugal pump and motor with maximum flow rate 80 Lpm and maximum head 18 m water – Turbine pump and motor with maximum flow rate 30 Lpm and maximum head 30 m water – Reciprocating pump and motor with reduction gear, maximum flow rate 15 Lpm at 300 rpm and maximum head 30 m water – 69 mm in axial flow pump and motor with metal impeller, guide vanes, shaft and casing, maximum flow rate 400 Lpm and maximum differential head 1.5 m water Reciprocating pump accessories - Pulse chambers with discharge isolating valve
- Pressure relief valve
Speed control Advanced inverter for controlling and indicating pump speed as well as for calculating motor input power alternatively by selector switches. Motor for all pumps Selector switch For operations of each pump alternatively Measuring instruments – Flow rates Water meter and stop watch for centrifugal, turbine and reciprocating pumps – Pressures - Pressure gauge for centrifugal, turbine and reciprocating pumps at common suction and outlet
- Differential pressure gauge for axial flow pump
– Pump speed and motor input power Advanced inverter – Sensors with digital display Flow rate for axial flow pump Software for data display and analysis by computer (separately supplied). Power supply 220 V, 1 Ph, 50 Hz. Other power supply is available on request. (0 reviews)