Turbine Test Set
Compact Pelton Turbine Test Set
This is a self contained bench top set for studying the Pelton turbine characteristics under various flow rates and heads.
The unit consists of a storage tank, a pump, a Pelton turbine, a dynamometer, and measuring instruments.
The adjustable nozzle directs the water jet to the runner buckets.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Torque vs speed at various heads and flow rates.
- Power output vs speed for various heads and flow rates.
- Efficiency vs speed for a given head and flow rate.
- Racing characteristics.
TECHNICAL DATATurbine: – Construction Stainless steel runner, nozzle and casing with transparent window to observe hydraulic action – Ratings Over 400 W of brake power Pump ratings – Motor 2.2 kW Dynamometer Water cooled mechanical brake absorber with anti splashing system Measuring instruments – Torque Spring balance – Pressure Pressure gauge – Sensors with digital display Flow rate and speeds Software for data display and analysis by computer (separately supplied). Power supply 220 V, 1 Ph, 50 Hz. Other power supply is available on request. (0 reviews) -
Air Flow and Thermodynamics
Compact Steam Turbine Power Plant 0.5 kW
The unit is designed to simulate modern steam power plant. Main components consist of a feed water system, a small industrial boiler, a steam turbine, a generator and lamp load, a condenser with a condensate tank and a pump, and a cooling tower. Accessories such as fuel tank, fuel flow meter, feed water meter, and a stack are also included. Instruments are provided for measurement of pressures, temperatures, output voltage and currents.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Measurement of feed water and fuel flow rates.
- Boiler efficiency, turbine generator efficiency, and overall power plant efficiency.
- Condenser heat transfer efficiency.
- Cooling tower efficiency.
TECHNICAL DATAThe boiler set consists of:
A . Boiler Unit: – Type Vertical, water tube – Rated heat output Approx. 63 kW (53,900 kcal/h) – Equivalent evaporation Approx. 100 kg/h steam – Maximum working pressure 10 kg/cm2 (0.98 MPa) – Measuring instruments - Pressure gauge for steam outlet
- Temperature sensors for feed water, boiler outlet and exhaust stack. (including ambient temperature)
– Safety devices - Safety valve
- Level gauge and switch at boiler
- Low level alarm
– Boiler accessories - Steam separator
- Stack, 2 x 2.4 m stainless steel with elbows
Burner: – Type Forced draft, pressure atomized – Control On-Off – Fuel Diesel or kerosene (LPG is available as an option.) Fuel system Stainless steel fuel tank, fuel strainer and fuel meter Feed water system: – Resin filter for public water. – Soft water tank. stainless steel – Water meter for steam rate monitoring Power supply 380 V, 3 Ph, 50Hz. Other power supply is available on request. B . Steam Turbine – Type Single stage, twin nozzle impulse turbine – Maximum electrical output Approx. 0.3 kW Measuring instruments: – Speed sensor for turbine – Temperature sensors for steam inlet and outlet – Pressure gauge for steam inlet – Water manometer for turbine outlet C . Generator and Lamp Load Voltage 220V, 1 Ph, 50 Hz. Load lamps 1 set. Measuring instruments – Generator speed digital display – Voltage and current digital display D. Condenser and Cooling Tower TH 101-013 Condenser Description : The unit allows a study of heat transfer in a heat exchanger as well as recover condensate for reuse.
– Type Steam tube – Accessories and instruments - Cooling water pump
- Water meter.
- Condensate tank.
- Stainless steel
- Temperature sensors for condensate, cooling water inlet and outlet
- Strainer
TH 135-014 Cooling Tower Description : This is an educational unit for recovering of condenser cooling water as well as
studying of cooling tower efficiencyE . Software for data display and analysis by computer (separately supplied). (0 reviews) -
Air Flow and Thermodynamics
Compact Steam Turbine Power Plant 1.0 kW
The unit is designed to simulate modern steam power plant. Main components consist of a feed water system, a small industrial boiler, a steam turbine, a generator and lamp load, a condenser with a condensate tank and a pump, and a cooling tower. Accessories such as fuel tank, fuel flow meter, feed water meter, and a stack are also included. Instruments are provided for measurement of pressures, temperatures, output voltage and currents.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Measurement of feed water and fuel flow rates.
- Boiler efficiency, turbine generator efficiency, and overall power plant efficiency.
- Condenser heat transfer efficiency.
- Cooling tower efficiency.
- Rankine cycle efficiency.
TECHNICAL DATAThe boiler set consists of:
A . Boiler Unit: – Type Vertical, water tube – Rated heat output 125 kW (107,000 kcal/h) – Equivalent evaporation Approx. 200 kg/h steam – Maximum working pressure 10 kg/cm2 (0.98 MPa) – Measuring instruments - Pressure gauge for steam outlet
- Temperature sensors for feed water, boiler outlet and exhaust stack (including ambient temperature)
– Safety devices - Safety valve
- Level gauge and switch at boiler
- Low level alarm
– Boiler accessories - Steam separator
- Stack, 2 x 2.4 m stainless steel with elbows
Burner: – Type Forced draft, pressure atomized – Control On-Off – Fuel Diesel or kerosene (LPG is available as an option.) Fuel system Stainless steel fuel tank, fuel strainer and fuel meter Feed water system: – Resin filter for public water. – Soft water tank. Stainless steel – Water meter for steam rate monitoring Power supply 380 V, 3 Ph, 50Hz. Other power supply is available on request. B . Steam Turbine – Type Single stage, twin nozzle impulse turbine – Maximum electrical output Approx. 0.6 kW Measuring instruments: – Speed sensor for turbine – Temperature sensors for steam inlet and outlet – Pressure gauge for steam inlet – Water manometer for turbine outlet C . Generator and Lamp Load Voltage 220V, 1 Ph, 50 Hz. Load lamps 1 set. Measuring instruments – Generator speed digital display – Voltage and current digital display D . Condenser and Cooling Tower TH 102-013 Condenser Description : The unit allows a study of heat transfer in a heat exchanger as well as recover condensate for reuse.
– Type Steam tube – Accessories and instruments - Cooling water pump
- Condensate transfer pump
- Water meter
- Condensate tank
- Stainless steel
- Temperature sensors for condensate, cooling water inlet and outlet
- Strainer
TH 136-014 Cooling Tower Description : This is an educational unit for recovering of condenser cooling water as well as studying of cooling tower efficiency. The unit consists of a cooling tower unit, a storage tank, a circulating pump and temperature gauges.
Technical data – Storage tank – Cooling tower capacity – Circulating pump – Wet bulb temperature sensor E . Software for data display and analysis by computer (separately supplied). (0 reviews) -
Air Flow and Thermodynamics
Compact Steam Turbine Power Plant 1.5 kW
The unit is designed to simulate modern steam power plant. Main components consist of a feed water system, a small industrial boiler, a steam turbine, a generator and lamp load, a condenser with a condensate tank and a pump, and a cooling tower. Accessories such as fuel tank, fuel flow meter, feed water meter, and a stack are also included. Instruments are provided for measurement of pressures, temperatures, output voltage and current.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Measurement of feed water and fuel flow rates.
- Boiler efficiency, turbine generator efficiency, and overall power plant efficiency.
- Condenser heat transfer efficiency.
- Cooling tower efficiency. Rankine cycle efficiency.
TECHNICAL DATAThe boiler set consists of:
A . Boiler Unit: – Type Vertical, water tube – Rated heat output 188 kW (162,000 kcal/h) – Equivalent evaporation Approx. 300 kg/h steam – Maximum working pressure 10 kg/cm2 (0.98 MPa) – Measuring instruments - Pressure gauge for steam outlet
- Temperature sensors for feed water, boiler outlet and exhaust stack (including ambient temperature)
– Safety devices - Safety valve
- Level gauge and switch at boiler
- Low level alarm
– Boiler accessories - Steam separator
- Steam pressure regulator
- Stack, 2 x 2.4 m stainless steel with elbows
Burner: – Type Forced draft, pressure atomized – Control On-Off – Fuel Diesel or kerosene (LPG is available as an option.) Fuel system Stainless steel fuel tank, fuel strainer and fuel meter Feed water system: – Resin filter for public water. – Soft water tank. Stainless steel – Water meter for steam rate monitoring Power supply 380 V, 3 Ph, 50Hz. Other power supply is available on request. B . Steam Turbine – Type Single stage, twin nozzle impulse turbine – Maximum electrical output Approx. 0.9 kW Measuring instruments: – Speed sensor for turbine – Temperature sensors for steam inlet and outlet – Pressure gauge for steam inlet – Water manometer for turbine outlet C . Generator and Lamp Load Voltage 220V, 1 Ph, 50 Hz. Load lamps 1 set. Measuring instruments D . Condenser and Cooling Tower TH 102-013 Condenser Description : The unit allows a study of heat transfer in a heat exchanger as well as recover condensate for reuse.
– Type Steam tube – Accessories and instruments - Cooling water pump
- Condensate transfer pump
- Water meter
- Condensate tank : Stainless steel
- Temperature sensors for cooling water inlet and outlet
- Strainer
TH 137-014 Cooling Tower Description : This is an educational unit for recovering of condenser cooling water as well as studying of cooling tower efficiency.
E . Software for data display and analysis by computer (separately supplied). (0 reviews) -
Pump Test Set
Compact Turbine Pump Test Set – Fixed Speed
This is a self-contained bench top unit for studying the turbine pump flow rate vs head at a fixed speed.
The unit consists of a storage tank and a turbine pump with motor on a steel base, and measuring instruments.
Instruction manual is also included.
TYPICAL EXPERIMENTSFlow rate vs head.
TECHNICAL DATAPump ratings – Maximum flow rate 35 Lpm – Maximum head 30 m water Measuring instruments – Pressure Pressure gauges at pump suction and discharge – Flow rate Water meter and stop watch Software for data display and analysis by computer (separately supplied). Power supply 220 V, 1 Ph, 50 Hz. Other power supply is available on request. (0 reviews) -
Pump Test Set
Compact Turbine Pump Test Set – Variable Speed
This is a self-contained bench top unit for studying the turbine pump flow rate vs head at various speeds.
The unit consists of a storage tank and a turbine pump with motor on a steel base, advanced inverter and measuring instruments.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Flow rate vs head.
- Pump input, output and overall efficiency at various speed.
TECHNICAL DATAPump ratings – Maximum flow rate 35 Lpm – Maximum head 30 m water Speed control Advanced inverter Measuring instruments – Pressure Pressure gauges at pump suction and discharge – Flow rate Water meter and stop watch – Speed and motor input power indicator Advanced inverter Software for data display and analysis by computer (separately supplied). Power supply 220 V, 1 Ph, 50Hz. Other power supply is available on request. (0 reviews) -
Turbine Test Set
Low Head Hydraulic Turbine Test Rig
This test facility was design and developed jointly with The Joint Graduate School of Energy and Environment (five institutions). It is intended to simulate large hydro power plant discharge for end user in designing small low head turbines.
The test rig provides water flow as well as measuring instruments. Flow is generated by a centrifugal pump. A head tank in front of the test section is provided to simulate a static head and another tank is provided after the test section. Flow rate and head can be varied by an inverter. A flow control valve at the pump discharge and a flow control valve of the return line between pump discharge and pump suction are provided. A dynamometer at the test section measures the designed turbine output.
The equipment is supplied unassembled and to be erected and commissioned at site.
Instruction manual is also included.
TYPICAL EXPERIMENTSThis is an ideal facility to simulate flow conditions of the actual site. The turbine input (flow rate and head) and output (speed and torque) can be accurately monitored. Thus, the most efficient prototype turbine can be designed, developed and tested.
TECHNICAL DATAPump ratings - Maximum flow rate 1300 m3/h
- Maximum head 15 m H2O
Circulating pipe 300 mm diameter Test section 300 mm diameter x 750 mm long Dynamometer Water brake absorber, 30 kW rating Head tank at upstream of test section 950 mm diameter x 3 m long Tail tank after test section 1430 mm diameter x 2.2 m long Sensors with digital display - Flow rate
- Turbine pressures at test section entrance and exit
- Speed
- Torque
Steel base frame with supports for tanks and pipings, test section platform with ladder. Software for data display and analysis by computer (separately supplied). Power supply 380V, 3Ph, 50Hz. Other power supply is available on request. (0 reviews) -
Hydraulic Studies and Accessories
Mini Axial Flow Impulse Turbine
The turbine twin nozzles with flow control valves direct water jets to the runner radial blades. Nozzle pressure is indicated by a pressure gauge. Torque is measured by a Prony brake with two spring balances. Speed is indicated on a portable tachometer. Flow rate is measured by the Hydraulics Bench measuring tank.
TYPICAL EXPERIMENTS- Efficiency of Axial flow impulse turbine
- Characteristic of Axial flow impulse turbine
- Turbine torque and power output versus speed and flow rate at various heads.
TECHNICAL DATAConstruction Stainless steel casing with transparent discharge window Maximum power 25 W Measuring instruments – Torque Spring balances – Speed Portable tachometer Software for data display and analysis by computer (separately supplied). (0 reviews) -
Turbine Test Set
Mini Axial Flow Impulse Turbine Demonstration Unit – Computer Interface
This is a self contained mini axial flow propeller turbine for studying the turbine characteristics with data analysis by computer.
The unit consists of axial flow propeller turbine with a dynamometer, a water storage tank, a low head high flow centrifugal pump, an interface box and input power sensors and software.
The turbine fixed guide vanes direct water to the runner. The interface box includes power supply to the sensors and motor, and a computer interface unit. It also provides interface ports to sensors and computer.
Instruction manual is also included.
TYPICAL EXPERIMENTS- Torque vs speed at various heads and flow rates.
- Power output vs speed for various heads and flow rates.
- Efficiency vs speed for a given head and flow rate.
- Racing characteristics.
TECHNICAL DATAConstruction Metal runner, twin nozzles and casing with transparent discharge section Ratings Maximum power over 25 W Dynamometer Mechanical brake Sensors with digital display Sensors with digital display Software for data display and analysis by computer (separately supplied). (0 reviews)